Hengzhong

Leave Your Message
 (2)  Molecular sieve dehydration and de-hydrocarbon removal device We use a combination process of natural gas freezing and molecular sieve dehydration device. The design scale is 1.5×104m3/d, with a load variation range of 30%~100%. After dehydration, when the natural gas water dew point is pressurized to the maximum pressure of 2.5MPa in the station, it is 5 ℃ or more lower than the minimum transportation environment temperature (when the molecular sieve is activated, the water dew point is controlled at -5 ℃). Client: PetroChina Gong108X Well1)Feed natural gas inlet conditions: flow rate: 1.5×104m3/d, Pressure: 1.6-2.5mpa. G, Temperature: 5-39 ℃2)Product gas conditions: flow rate: 0.7~1.5 × 104m3/d Pressure: 1.5~2.4mpa. G Temperature: 29 ℃